供貨周期 | 現貨 |
---|
我司所售的蓄電池保證是原廠原裝產品,,簽訂合同,并提供,
38AH以上出現非人為質量問題三年內免費更換同等型號的全新電池,請廣大客戶放心采購!-
![]() |
參考價 | 面議 |
更新時間:2020-11-02 15:04:23瀏覽次數:351
聯系我們時請說明是化工儀器網上看到的信息,謝謝!
法國Power Sonic蓄電池PS-12450B 12V45AH
法國Power Sonic蓄電池PS-12450B 12V45AH
Power-Sonic一直是主導力量在電池業(yè)務超過46年。由于我們的承諾我們公司蓬勃發(fā)展提供高質量的成本有效的電池,支持水平的服務是的。
我們驕傲我們的靈活性和能力迅速采取行動為市場帶來新的行業(yè)產品。我們很自豪持有ISO 9001認證覆蓋我們的組織的各個方面。
What is a AGM or Absorbed Glass Mat Battery?
The newer type of sealed nonspillable maintenance free valve regulated battery uses "Absorbed Glass Mats", or AGM separators between the plates. This is a very fine fiber Boron-Silicate glass mat. These type of batteries have all the advantages of gelled, but can take much more abuse. These are also called "starved electrolyte.” Just like the Gel batteries, the AGM Battery will not leak acid if broken.
1、逆變器功率級一對功放晶體管損壞,更換同型號晶體管后,運行一段時間又燒壞的原因是電流過大,而引起電流過大的原因有:
——過流保護失效。當逆變器輸出發(fā)生過電流時,過流保護電路不起作用;
——脈寬調制(PWM)組件故障,輸出的兩路互補波形不對稱,一個導通時間長,而另一個導通時間短,使兩臂工作不平衡,甚至兩臂同時導通,造成兩管損壞;
——功率管參數相差較大,此時即使輸入對稱波形,輸出也會不對稱,該波形經輸出變壓器,造成偏磁,即磁通平衡,積累下去導致變壓器飽和而電流驟增,燒壞功率管,而一只燒壞,另一只也隨之燒壞。
2、蓄電池電壓偏低,但開機充電十多小時,蓄電池電壓仍充不上去。
故障分析:從現象判斷為蓄電池或充電電路故障,可按以下步驟檢查:
——檢查充電電路輸入輸出電壓是否正常;
——若充電電路輸入正常,輸出不正常,斷開蓄電池
再測,若仍不正常則為充電電路故障;
——若斷開蓄電池后充電電路輸入、輸出均正常,則說明蓄電池已因長期未充電、過放或已到壽命期等原因而損壞。
3、有市電時UPS輸出正常,而無市電時蜂鳴器長鳴,無輸出。
故障分析:從現象判斷為蓄電池和逆變器部分故障,可按以下程序檢查:(相關內容:UPS價格)
——檢查蓄電池電壓,看蓄電池是否充電不足,若蓄電池充電不足,則要檢查是蓄電池本身的故障還是充電電路故障。
——若蓄電池工作電壓正常,檢查逆變器驅動電路工作是否正常,若驅動電路輸出正常,說明逆變器損壞。
——若逆變器驅動電路工作不正常,則檢查波形產生電路有無PWM控制信號輸出,若有控制信號輸出,說明故障在逆變器驅動電路。
——若波形產生電路無PWM控制信號輸出,則檢查其輸出是否因保護電路工作而封鎖,若有則查明保護原因;
——若保護電路沒有工作且工作電壓正常,而波形產生電路無PWM波形輸出則說明波形產生電路損壞。
上述排故順序也可倒過來進行,有時能更快發(fā)現故障。
4、UPS開機后,面板上無任何顯示,UPS不工作。
故障分析:從故障現象判斷,其故障在市電輸入、蓄電池及市電檢測部分及蓄電池電壓檢測回路:
——檢查市電輸入保險絲是否燒毀;
——若市電輸入保險絲完好,檢查蓄電池保險是否燒毀,因為某些UPS當自檢不到蓄電池電壓時,會將UPS的所有輸出及顯示關閉;
——若蓄電池保險完好,檢查市電檢測電路工作是否正常,若市電檢測電路工作不正常且UPS不具備無市電啟動功能時,UPS同樣會關閉所有輸出及顯示。
What are the advantages of the AGM battery?
The advantages of AGM batteries are no maintenance, sealed against fumes, hydrogen, leakage, or non-spilling even if they are broken, and can survive most freezes. AGM batteries are "recombinant" – which means the Oxygen and Hydrogen recombine inside the battery. These use gas phase transfer of oxygen to the negative plates to recombine them back into water while charging and prevent the loss of water through electrolysis. The recombining is typically 99+% efficient, so almost no water is lost. Charging voltages for most AGM batteries are the same as for a standard type battery so there is no need for special charging adjustments or problems with incompatible chargers or charge controls. Since the internal resistance is extremely low, there is almost no heating of the battery even under heavy charge and discharge currents. AGM batteries have a very low self-discharge rate (from 1% to 3% per month). So they can sit in storage for much longer periods without charging. The plates in AGM's are tightly packed and rigidly mounted, and will withstand shock and vibration better than any standard battery.
模型 | 電壓 | 容量 | 容量 | ||||||
V | 20小時 | 10小時 | 長 | 寬 | 高 | 總高 | 公斤 | ||
PG-12V28 FR | 12 | 28 | 28.0 | 167 | 177 | 125 | 125 | 8.4 | T12 |
PG-12V35 FR | 12 | 36 | 35.0 | 196 | 130 | 158 | 177 | 11.1 | T6 |
PG-12V42 FR | 12 | 45 | 42.0 | 197 | 165 | 170 | 156 | 14.5 | T6 |
PG-12V55 FR | 12 | 60 | 56.0 | 230 | 138 | 207 | 228 | 16.3 | T6 |
PG-12V65 FR | 12 | 70.6 | 65.0 | 348 | 167 | 178 | 159 | 21.3 | T6 |
PG-12V75 FR | 12 | 80 | 75.0 | 348 | 167 | 178 | 164 | 24.6 | T6 |
PG-12V75T FR | 12 | 80 | 75.0 | 260 | 168 | 210 | 216 | 24.6 | T6 |
PG-12V100 FR | 12 | 104.0 | 100.0 | 306 | 168 | 210 | 216 | 31.5 | T6 |
PG-12V103 FR | 12 | 111 | 103.0 | 330 | 173 | 212 | 220 | 31.8 | T11 |
PG-12V120 FR | 12 | 129 | 124.0 | 410 | 177 | 211 | 226 | 37.2 | T11 |
PG-12V140 FR | 12 | 154 | 144.0 | 343 | 171 | 274 | 280 | 45.9 | T11 |
PG-12V150 FR | 12 | 166 | 153.0 | 485 | 170 | 242 | 224 | 46.??7 | T11 |
PG-12V200 FR | 12 | 226 | 210.0 | 522 | 240 | 218 | 224 | 64.1 | T11 |
Latest News
Recycle-More.co.uk
Power-Sonic Europe Ltd is committed to its obligations as a producer of both industrial and portable batteries. Please note the summary of our take back policy:
Take back policy summary
PSE Account holders
VRLA (SLA) - Industrial & Portable
a) Sufficient waste to fill 1000kg bin 4 times per annum. Contact sales@power-sonic.co.uk to arrange placement of a bin at your premises
b) Smaller quantities of waste (Minimum of 10kgs). Contact Valpak directly 08450 682 572 (option 6)
NON VRLA - Industrial
Subject to conditions (see download on Take Back Policy) contact
sales@power-sonic.co.uk for collection
NON VRLA - Portable
Contact Valpak directly 08450 682 572 (option 6) Minimum 10kgs
Non Account holders - Portable batteries
Distributors - Contact Valpak directly 08450 682 572 (option 6) Minimum 10kgs
Non distributors - Contact Valpak directly 08450 682 572. Minimum 10 units
交流電源線分為零線(標志字母為"N"Neutralwire)和火線(標志字母為"L"LiveWire)。以及與大地相連的導線;
火線、零線、地線都是連接在三孔插座的導線,火線與零線之間保持呈正弦振蕩式的壓差。由于大地和零線電位相同,故火線與地線也保持呈正弦振蕩式的壓差。
當人體接觸火線時,人是站在地上的,火線的電流通過人體流入大地或者零線,會發(fā)生觸電事故,而接觸零線則不會被電擊的。把外殼能導電的用電器的外殼與地線連接,在漏電的情況下,電流會直接通過地線流入大地而不通過身體,從而避免發(fā)生觸電事故。
零線帶電是沒有良好接地的體現,如果良好接地了,電流會流入地下,用試電筆不會檢測出來。如果用試電筆檢測出零線帶電,要么是零線斷了,要么是接觸不好。因此,這不是零線帶電的原因。
原因分析
正常情況下,零線上不應該有電。所以,一旦有電,肯定是故障的表現;zui簡單的就是電磁感應,而且這時候零線沒有良好接地,未能形成回路;
其次,用電設備漏電或者相線碰殼,但是電流不算大,因此還沒有跳閘。在三相四線制的供電系統中,如果零線接地不好或者接地端斷了,其后果是在三相負載不平衡時使零線的電位不等于0,也就是說中性點發(fā)生偏移。
具體零線電位多少與三相負載不平衡度有關,越不平衡,中性點偏移就越大,零線的電位就越高。零線電位偏移后三相的相電壓一般就不是220V了。有的相可能超過220V,有的相則可能低于220V。
當中性點偏移量太大,三相的相電壓增加的相就可能使其用電電器燒毀,三相的相電壓減少的相就可能使其用電電器不能工作。零線的電位升高后,達到一定的值時觸地線將會造成觸電事故危險。
常見零線帶電的原因及解決辦法
1、線路上有電氣設備漏電,而保護裝置末動作,使零線帶電。
解決辦法:停電進行檢修,找出漏電的設備進行修復,并查找保護裝置末動作的原因。
2、線路上有一相接地,電網中的總保護裝置末保護,使零線帶電。
解決辦法:停電后,首先用搖表對線路進行測量,看線路是否有絕緣不好的地方,測量時要注意線路中的儀表要斷開。
3、零線斷裂,在斷裂處后面的電氣設備中有漏電或有較大的單相負荷運行,使零線帶電。
解決辦法:停電后測試零線是否斷裂,對斷裂的零線進行查找并修復。
4、在接零電網中,有個別電氣設備采取保護接地而且漏電,使零線帶電。
解決辦法:分清系統是接零系統還是接地系統,亦或是接零系統中進行了重復接地。然后進行正確的安裝地線。
5、在接零電網中,有單相電氣設備采用“一火一地”,即無工作零線,使零線帶電。
解決辦法:安裝N線,不能把PE線當成N線用。
6、在電網中有的電氣設備絕緣電阻,已有所破壞而漏電,使零線帶電。
解決辦法:檢查出絕緣電阻不符合規(guī)定的要求的設備,進行修理。
7、在變壓器低壓側工作接地連接處接觸不良,有較大的電阻,在三相負荷不平衡電流超過允許范圍時,使零線帶電。
解決辦法:接觸不良不好查找,要每年或按規(guī)定的時間進行檢修,要按規(guī)程進行檢修。
8、高壓竄入低壓,使零線帶電。
解決辦法:不好查找,有時還會出大問題。zui難對付的一種,威脅人身安全。一定要按操作規(guī)程去操作。
9、高壓采取二線一地運行方式,其接地體與低壓工作接地或重復接地體相距太近時,高壓工作接地上的電壓降,影響低壓側工作接地,使零線帶電。
解決辦法:查出原因,按相應的規(guī)程進行敷設。
10、磁場感應引起零線帶電。
解決辦法:防止發(fā)生磁場感應。
11、靜電感應引起零線帶電。
解決辦法:防止發(fā)生靜電感應。
由于網頁資源有限,具體電池型號、參數、價格咨詢請致電。另外我們還為客戶提供技術咨詢服務,說出您的負載、延時時間等,我們會有專業(yè)的工程師為您提供ups電源、電池解決方案,讓您真正的后顧無憂!