產(chǎn)品簡(jiǎn)介
讀數(shù)模式(不保存數(shù)據(jù)),曲線模式(保存數(shù)據(jù))取樣率:讀數(shù)模式-5Hz(0.2秒一個(gè)讀數(shù)),曲線模式-200Hz(0.005秒一個(gè)讀數(shù))
測(cè)試時(shí)間:最長(zhǎng)2分鐘30秒
儀器可保存10個(gè)曲線圖,可輸出到電腦
待機(jī)10分鐘無(wú)操作自動(dòng)關(guān)機(jī)
![]() |
蘇州渤遠(yuǎn)弘電子有限公司 |
—— 銷售熱線 ——
13913132816 |
19431人體行走靜電測(cè)試儀
19431人體行走靜電測(cè)試儀產(chǎn)品特性
測(cè)試人體行走所產(chǎn)生的靜電壓,用于評(píng)估防靜電鞋-地板綜合靜電消散性能
讀數(shù)模式(不保存數(shù)據(jù)),曲線模式(保存數(shù)據(jù))
量程:0~+/-1050V
分辨率:1V
測(cè)試精度:+/-5V(100V以內(nèi)),+/-5%(100V-1050V)
輸入阻抗:1014 Ω
取樣率:讀數(shù)模式-5Hz(0.2秒一個(gè)讀數(shù)),曲線模式-200Hz(0.005秒一個(gè)讀數(shù))
測(cè)試時(shí)間:最長(zhǎng)2分鐘30秒
儀器可保存10個(gè)曲線圖,可輸出到電腦
19431人體行走靜電測(cè)試待機(jī)10分鐘無(wú)操作自動(dòng)關(guān)機(jī)
19431人體行走靜電測(cè)試工作電源:6節(jié)AA電池
訂貨號(hào)
19431人體行走靜電測(cè)試套件,包含以下物品
測(cè)試表
握柄電極和連接線
數(shù)據(jù)線(8針端子-USB端子)
接地線(5米長(zhǎng))
接地插頭(貨號(hào)09838C)
Body Voltage Meter Installation, Operation and Maintenance Description The Desco 19431 Body Voltage Meter is a portable measuring system that allows analysis of charge levels accumulated on the human body according to ANSI/ ESD STM97.2. The Body Voltage Meter measurement may be logged using internal memory. Logged measurements can be exported and further reviewed on a PC. Graphs of measurements can be displayed on the LCD display for quick evaluation. Each Body Voltage Meter is calibrated with accepted procedures and standards traceable to the National Institute of Standards and Technology (NIST). October 2023 “A compliance verification plan shall be established to ensure the organization’s fulfilment of the requirements of the plan. Process monitoring (measurements) shall be conducted in accordance with a compliance verification plan that identifies the technical requirements to be verified, the measurement limits and the frequency at which those verifications shall occur. The compliance verification plan shall document the test methods used for process monitoring and measurements. If the organization uses different test methods to replace those of this standard, the organization shall be able to show that the results achieved correlate with the referenced standards. Where test methods are devised for testing items not covered in this standard, these shall be adequately documented including corresponding test limits. Compliance verification records shall be established and maintained to provide evidence of conformity to the technical requirements. The test equipment selected shall be capable of making the measurements defined in the compliance verification plan." (EN 61340-5-1 clause 5.2.4) Packaging 1 Body Voltage Meter 1 Walking Test Probe 1 Black 8-Pin DIN to USB Cable, 1.8 m long 1 Black Ground Cord with Crocodile Clip, 5 m long 1 Lanyard with Hook