Model 205
Two Conductors,
4 Amps

 

High-speed model available (205-H)
Low-torque/low-temp. models available (205-L)
Available with stainless steel ball bearings (205-SS)

 

 

Model No.

Terminals

Voltage
AC/DC

Amp
Rating
@240VAC

Max.
Freq.
MHz

Contact
Resistance

Max.
RPM

Temp
Max. F (C) /
 Min. F (C)

Rotation
Torque (gm-cm)

Circuit
Separation

 

205

2

0-250

4

200

<1m

 

2000

140 (60) /45(7)

75

>25M

 

205-SS

2

0-250

4

200

<1m

 

2000

140 (60) /45(7)

75

>25M

 

205-L

2

0-250

4

200

<1m

 

1200

140 (60) /-20(-29)

20

>25M

 

205-LS

2

0-250

4

200

<1m

 

1200

140 (60) /-20(-29)

75

>25M

 

205-H

2

0-250

4

200

<1m

 

3600

140 (60) /45(7)

35

>25M

 

205-HS

2

0-250

4

200

<1m

 

3600

140 (60) /45(7)

35

>25M

 

"SS" designator indicates stainless steel ball bearing (recommended for wet or corrosive environments)
"L" designator indicates low torque / low temp.
"LS" designator indicates low temp. & stainless steel ball bearing
"H" designator indicates high RPM
"HS" designator indicates high RPM & stainless steel ball bearing

205 Accessories

 

592
two contact receptacle 
w/ 6" wires
(18 AWG)

591
two contact receptacle
w/ one 6" wire
(18 AWG)

594
two contact receptacle 
w/ two solder holes
for 18 AWG wires

595
two contact cap
w/ two solder lugs

 

 

 

205 Connections

 

 

205 Suggested Mounting Methods

 

 

Receptacle Mount Hole Dimensions

MODEL

HOLE DIAMETER (Ø) *

DEPTH

591, 592, 594

.283"    (7.19)

.35"    (8.89)

*Inch  (mm) Tolerance Ø 

+.001" (+.025)

 

 

  

 -.000" (-.000)

 

 

 

 

 











 

Installation Notes:

  • the up arrow should not point below horizontal
  • do not solder to or bend connector tabs
  • avoid lateral forces and mechanical loads (overly stiff or tight wires)
  • do not rigid mount both ends of connector
  • limit mounting eccentricity (runout / wobble) to .005" (.13mm)
  • provide overload protection within the circuit
  • avoid vibration and bumping motions

 

 

 