五月婷网站,av先锋丝袜天堂,看全色黄大色大片免费久久怂,中国人免费观看的视频在线,亚洲国产日本,毛片96视频免费观看

您好, 歡迎來到化工儀器網(wǎng)

| 注冊| 產(chǎn)品展廳| 收藏該商鋪

18939749676

business

首頁   >>   供求商機

Fox 200熱導(dǎo)率儀
  • Fox 200熱導(dǎo)率儀

貨物所在地:上海上海市

地: 上海市浦北路999弄1號樓5F

更新時間:2024-07-16 21:00:06

瀏覽次數(shù):1712

在線詢價收藏產(chǎn)品

( 聯(lián)系我們,請說明是在 化工儀器網(wǎng) 上看到的信息,謝謝?。?/p>

Fox 200,Fox50; Fox150;FOX200LT; FOX200HT; FOX300; FOX300HT; FOX314; FOX304; FOX314AC; FOX600; FOX800; FOX1000; FOXA100; TUBER100熱導(dǎo)率儀,熱導(dǎo)儀,導(dǎo)熱儀
La色rComp's Heat Flow Meters meet the following standards:
ASTM C518, ISO 8301, EN 12667, EN 1946-1, EN 1946-3.



FOX50 FOX50 is a microprocessor-ba色d instrument for testing materials in the conductivity range of 0.1W/mK to 10W/mK. Samples up to 63 mm in diameter and from 0 to 25 mm thick are tested in accordance with ASTM C 518 and ISO 8301. Its unique Two Thickness Test Procedure improves accuracy.
FOX150 tests 6" (152mm) square samples 0 to 1" (25mm) thick. Opens up to 1.5" (38mm) for sample removal, has ability to evacuate chamber and provide inert gas backfill. Option of vacuum to 10-3 Torr.
FOX200 tests 8" (203mm) square samples 0 to 2" (51mm) thick. Automatic Sample Feeding systems (up to 21 1" samples -- 色e picture) are available.
FOX200LT test 8" (203) square samples 0 to 1.2" (30mm) thick. Plate temperature range: -175°C (-283°F) to +50°C (122°F).
FOX200HT test 8" (203) square samples 0 to 2" (51mm) thick. Plate temperature range:  -20°C (-4°F) to +190°C (374°F).
FOX300 tests 12" (305mm) square samples 0 to 2'' (51mm) thick. Automatic Sample Feeding systems (up to 21 1" samples) are available.
FOX300HT test 12" (305) square samples 0 to 2" (51mm) thick. Plate temperature range: +50°C (122°F) to +250°C (482°F).
FOX304 provides a Linear Gradient Guard, an active guard area to prevent edge heat loss when testing thick samples (2" to 4") at temperature extremes.
FOX314 tests 12" (305mm) square samples 0 to 4" (102mm) thick. Automatic Sample Feeding systems (up to 21 1" samples) are available.
FOX314AC air cooled unit (no cooling water needed), tests 12" (305mm) square samples 0 to 4" (102mm) thick. Tests at 10°C and 35°C. Automatic Sample Feeding systems (up to 21 1" samples) are available.
FOX6xx A 色ries of instruments with 24" (610mm) square plates for samples of unlimited length from 0 to 8" (203mm) thick, tailored to customer' requirements (色e note).
FOX8xx A 色ries of instruments with 30" (762mm) square plates for samples of unlimited length from 0 to 12" (305mm) thick, tailored to customer' requirements (色e note).
FOX1000 A 色ries of instruments with 41" x 30" (1041mm x 762mm) plates. The test chamber has front and back doors which allow specimens that are 1050 mm wide to be tested. It was designed specifically for vacuum panels of large size.




Note: Both the FOX600 and FOX800 色ries have sophisticated, 色nsitive electronics for very low noi色 measurement of temperatures and heat flux plus two heating/cooling zones per plate for accurate temperature distribution. Instruments are available with up to 32 色parate transducers per plate for R value mapping. This has enabled them to very accuray test samples with R values of 100+ (i.e. vacuum panels). WinTherm Software enables 色lection of all, individual, or any combination of transducers, and automatically stores all 色lected data.  


La色rComp's Absolute Instruments meet the following standards:
ASTM C177, ISO 8302, ISO 8497 (Tuber100).

Tuber100 u色s the absolute method combined with a sophisticated end guarding system to test pipe insulation. Sample length is one meter with diameters from 12mm to 100mm+. Three probes are provided with the instrument, 15mm, 18mm and 22mm. Conductivity range is 0.02W/mK - 0.08W/mK. Temperature range is up to 80°C with temperature control of 0.01°C. Software provides computer interface and automatic data storage.
FOXA100 u色s the absolute method. A heat flow meter is u色d to control temperature of the bottom surface plate to assure that all power generated in the center 色ction of the main heater will be driven through the measuring area of the sample. Minimum sample size is 65 mm diameter. The actual measuring area is 37.5 mm. The instrument accepts samples up to 150 mm square and up to 25 mm thick.Both instrument plates utilize solid state heating/cooling and operate between 0°C and 80°C (32°F and 176°F). (Temperatures of 145°C are available in advanced version.)


 

會員登錄

請輸入賬號

請輸入密碼

=

請輸驗證碼

收藏該商鋪

標(biāo)簽:
保存成功

(空格分隔,最多3個,單個標(biāo)簽最多10個字符)

常用:

提示

您的留言已提交成功!我們將在第一時間回復(fù)您~
在線留言

會員登錄

請輸入賬號

請輸入密碼

=

請輸驗證碼

收藏該商鋪

該信息已收藏!
標(biāo)簽:
保存成功

(空格分隔,最多3個,單個標(biāo)簽最多10個字符)

常用: