五月婷网站,av先锋丝袜天堂,看全色黄大色大片免费久久怂,中国人免费观看的视频在线,亚洲国产日本,毛片96视频免费观看

產(chǎn)品展廳收藏該商鋪

您好 登錄 注冊(cè)

當(dāng)前位置:
蘇州賽秘爾電子科技有限公司>>阻抗分析儀>>wk-6530B高精度阻抗分析儀

高精度阻抗分析儀

返回列表頁(yè)
  • 高精度阻抗分析儀

  • 高精度阻抗分析儀

收藏
舉報(bào)
參考價(jià) 18
訂貨量 1
具體成交價(jià)以合同協(xié)議為準(zhǔn)
  • 型號(hào) wk-6530B
  • 品牌
  • 廠商性質(zhì) 生產(chǎn)商
  • 所在地 蘇州市

在線詢價(jià) 收藏產(chǎn)品 加入對(duì)比 查看聯(lián)系電話

更新時(shí)間:2016-11-26 14:20:49瀏覽次數(shù):1961

聯(lián)系我們時(shí)請(qǐng)說(shuō)明是化工儀器網(wǎng)上看到的信息,謝謝!

產(chǎn)品簡(jiǎn)介

wk-6530B高精度阻抗分析儀 6500
功能 6505B 6510B 6515B 6520B 6530B 6550B 65120B 頻率范圍 20Hz–5MHz 20Hz–10MHz 20Hz–15MHz 20Hz–20MHz 20Hz–30MHz 20Hz–50MHz 20Hz–120MHz 基本精確度 0.05% 頻率精確度 ±0.005%

詳細(xì)介紹

 

wk-6530B高精度阻抗分析儀介紹

量測(cè)參數(shù)

Z, Ø, L, C, R, Q, D, Y, G, B, X

輸出

10mV to 1V rms, 200uA to 20mA rms

顯示格式

串/并聯(lián)電路,或兩極式

wk-6530B高精度阻抗分析儀圖形分析模式

任選兩種參數(shù)依頻率, 驅(qū)動(dòng)值及直流偏壓源掃描

wk-6530B電表模式

可當(dāng)標(biāo)準(zhǔn)LCR電表使用

待測(cè)元件連接

可通過(guò)面板的BNC接頭來(lái)實(shí)現(xiàn)倆端,三端或四埠的連接以及可能的接地狀況.備有許多的可選附件以供不同的測(cè)試需要.

wk-6530B量測(cè)精度

消耗因素: ±0.0005(1+D*D2)

品質(zhì)因素: ±0.05%(Q + 1/Q)

電容/電感/阻抗: ± 0.05

 

The 6500B series of Precision Impedance Analyzers provide precise and fast testing of components at frequencies up to 120 MHz. Basic measurement accuracy is ±0.05% making the instruments the best in the class.

The accuracy and versatility makes the precision analyzers the ideal choice for many different tasks and applications including passive component design, dielectric material characterisation and manufacturing test.

Engineers need to evaluate component characteristics at high frequencies with high levels of accuracy. The 65120B 120 MHz Precision Impedance Analyzer is therefore ideal for many demanding tasks, combining accuracy and ease of use at an affordable price. If a frequency range up to 120 MHz is not required then other models are available. The 6505B 5MHz instrument is the entry level model in the range.

 

 

High measurement accuracy

 

 

Capacitance, inductance and impedance basic accuracy is an excellent ±0.05%. Dissipation factor accuracy is ±0.0005 and the quality factor accuracy is ±0.05%.

 

 

Graphical sweep of components

 

 

 

 

 

 

 

Variable drive and bias levels

 

 

AC drive levels up to 1V or 20mA can be selected to evaluate components in realistic operating environments.
The /D1 DC bias option provides 0 to +40V dc bias voltage and 0 to +100mA dc bias current while the /D2 option provides -40V to +40V dc bias voltage.

 

 

External control

 

 

The GPIB interface is used to control the instrument and read back measured values for applications such as quality control or for archiving purposes.

An Ethernet interface similarly allows the instrument to be controlled and to send out data - allowing it to be integrated into many test environments.

 

 

Wide range of interfaces

 

 

An external monitor or projector may be connected to the instrument. The ability to provide a large screen display is invaluable in production environments or for teaching and training.

Instrument control from both a keyboard and mouse is available. Any keyboard or mouse, with either PS/2 or USB interfaces, can be simply connected to provide an alternative method of instrument control and operation.

 

 

Data storage and retrieval

 

 

All measurement and setup data can be stored using the Ethernet interface or a USB flash memory (supplied as standard).

 

 

Setup data

 

 

Up to 20 instrument setups may be stored locally for each mode.

 

 

Bin handling

 

 

The /B1 option (non-isolated 5V) or /B2 option (isolated 24V) signals are available through a 25-way D-type connector. 10 bins can be set using absolute or percentage limits.

 

 

Printer outputs

 

 

Hard copy printouts can be obtained in a number of ways including direct to an HP-PCL compatible graphics printer or Epson compatible text/ticket printer. A networked HP-PCL compatible printer may also be used via Ethernet connection.

 

 

Component connections

 

 

Four front panel BNC connectors permit three or four terminal connections with the screens at ground potential.
The 1J1011 component fixture, supplied as standard, ensures optimum performance when measuring a wide range of components of leaded components and devices.
1J1012 (2 Terminal) and 1J1014 (4 Terminal) fixtures allow connection to surface mount devices.

 

 

Protection against charged capacitors

 

 

High precision measuring instruments can be damaged by charged capacitors which can cause costly repairs and unacceptable downtime. All the models in the range incorporate protection against charged capacitors.

 

 

Comprehensive and precise component tests at higher frequencies

 

 

The 6500B series capabilities are best summarised by “Comprehensive and precise component tests at higher frequencies”. The instruments are the perfect solution for those who have demanding component measurement needs.

 

 

Technical Specifications:

 

 

Measurement Function

Capacitance (C)
Inductance (L)
Resistance (R)
Reactance (X)
Conductance (G)
Susceptance (B)
Dissipation Factor (D)
Quality Factor (Q)
Impedance (Z)
Admittance (Y)
Phase Angle (Ø)

Frequency Range

6505B 20Hz to 5MHz
6510B 20Hz to 10MHz
6515B 20Hz to 15MHz
6520B 20Hz to 20MHz
6530B 20Hz to 30MHz
6550B 20Hz to 50MHz
65120B 20Hz to 120MHz

Frequency step size 0.1 mHz
Accuracy of set frequency ±0.005"%

AC Drive Level

10 mV or 1V rms (varies with frequency)
200 µA to 20 mA rms (varies with frequency)

Measurement Speeds

4 speeds selectable
Up to 20 measurements per second for test frequencies ≥100 Hz

Accuracy

Dissipation factor - ±0.0005 (1+D2)
Quality factor - ±0.05 %( Q+1/Q)
Capacitance / Inductance / Impedance - ±0.05%
Accuracy varies with frequency, drive level and measured impedance

DC Bias Current (Option)

/D1 0 to +100mA dc bias current and 0 to +40V dc bias voltage
/D2 -40V to +40V dc bias voltage

Binning (Option)

10 bins with absolute and percentage limits
25 way d-type interface connector
/B1 (Non-isolated) Comon 0V Bin outputs 0 to 5V(normal) with >10mA current sink capability
/B2 (isolated) Comon 24V input outputs 0 to 24V with >10mA current source capability

 

 

General Data:

 

 

Input Specification

Power supply - Input voltage 90 V AC to 264 V AC (Autoranging)
Mains frequency 47 to 63 Hz

Display

8.4" VGA (650 x 480) color TFT with touch panel

Measurement Connections

Four front panel BNC connectors permit two, three or four terminal connections with the screens at ground potential.
1J1011 Component Fixture (supplied as standard) allows connection to leaded components and devices.

Printer

HP-PCL compatible graphics printing (local and network)
Centronics / parallel printer port, Epson compatible text/ticket printing (local)

Remote Trigger

Rear panel BNC with internal pull-up, operates on logic low or contact closure

GPIB Interface

External instrument control 24 pin IEEE 488 connector

USB Interface

Two Unversal Serial Bus (USB) interfaces
USB 1.1 compliant

VGA Interface

15-way D-type connector to drive an external monitor in addition to the internal screen

Network Interface

10/100-BASETX Ethernet controller
RJ45 connector

Keyboard Interface

Standard USB or PS/2 keyboard port. Instrument front panel remains active with keyboard plugged in

Mouse Interface

Standard USB or PS/2 mouse port
Touch screen remains enabled when the mouse is connected

 

收藏該商鋪

請(qǐng) 登錄 后再收藏

提示

您的留言已提交成功!我們將在第一時(shí)間回復(fù)您~

對(duì)比框

產(chǎn)品對(duì)比 產(chǎn)品對(duì)比 聯(lián)系電話 二維碼 意見(jiàn)反饋

掃一掃訪問(wèn)手機(jī)商鋪
86-0512-62519606
在線留言