五月婷网站,av先锋丝袜天堂,看全色黄大色大片免费久久怂,中国人免费观看的视频在线,亚洲国产日本,毛片96视频免费观看

上海京燦精密機械有限公司
中級會員 | 第9年

17717563696

當前位置:上海京燦精密機械有限公司>>美國SKC大氣采樣泵>> 美國SKC Biolite微生物采樣泵

美國SKC Biolite微生物采樣泵

參  考  價面議
具體成交價以合同協(xié)議為準

產(chǎn)品型號

品       牌SKC/美國

廠商性質(zhì)生產(chǎn)商

所  在  地上海

更新時間:2017-08-04 17:24:24瀏覽次數(shù):1588次

聯(lián)系我時,請告知來自 化工儀器網(wǎng)
同類優(yōu)質(zhì)產(chǎn)品更多>
美國SKC Biolite微生物采樣泵套裝產(chǎn)品實拍圖,氣象監(jiān)測站,防疫工作站采樣泵,上海京燦精密機械致力于未來,提供*品質(zhì)的實驗室和工業(yè)檢測儀器設備。

美國SKC Biolite微生物采樣泵

技術參數(shù):

zui大流速Maximum flow rate: 30.5 litre/min;
背壓流速:Maximum back pressure: 800mbar;
尺寸:Dimensions: W x H x D 162 x 209 x 338mm;
重量:Weight: 6.05kg;
防護等級Enclosure rating - IP20
操作溫度Operating temperature: 0°C to +40°C
操作濕度Operating humidity: 0 to 95% Rh
電壓Mains supply: 220/230V ~ 50Hz
電流Maximum input current: 0.66A
噪音Operating noise level: 67 - 71dBA @ 1metre

找到一個合適的電源插座,在泵背部插入電源引入IEC電源,規(guī)格為:英國3針和2歐元引腳電源引線,選擇正確插頭。

打開流量調(diào)節(jié)器,*逆時針方向以確保它是*開放的,然后打開電源開關。

打開泵的開/關,使泵運行五~十分鐘穩(wěn)定之前任何流量校準,關機,停止泵。

打開泵的開關。如果使用流量調(diào)節(jié)器需要調(diào)節(jié)流量。打開流量調(diào)節(jié)器順時針和逆時針降低流動率增大流量。使泵運行五分鐘,流量穩(wěn)定在采取任何刻度讀數(shù)。當所需的流量已定,流量調(diào)節(jié)器可以用鎖緊螺母鎖緊。

背壓力表給出一個,這個指示的SKC BioSampler正確操作r達到吸15in汞音速。

Insert the mains lead into the IEC mains inlet at the rear of the pump and plug the lead into a suitable mains outlet socket. Both UK 3 pin and Euro 2 pin mains leads are supplied with the unit, select the correct lead for your location.

Turn the flow adjuster fully counter-clockwise to ensure that it is fully open. Switch on the mains supply.

Switch on the pump using the on/off switch at the rear of the pump. Allow the pump to run for five to ten minutes to stabilise before commencing any flow calibration. Switch the pump off using the on/off switch at the rear of the pump.

Connect the sample train to the pump inlet hosetail. Switch on the pump using the on/off switch. Adjust the flow rate if required using the flow adjuster. Turn the flow adjuster clockwise to reduce the flow rate and anti-clockwise to increase the flow rate. Allow the pump to run for five minutes for the flow rate to stabilise before taking any calibration readings. When the desired flow rate has been set, the flow adjuster can be locked using the locking nut.

The back pressure gauge gives a reading of the suction generated by the pump due to the restriction to flow of the sample train. This is important for indicating correct operation of the SKC Biosampler - the Biosampler achieves sonic flow at a suction of 15in Hg (refer to the Biosampler instructions for further details).

美國SKC具備優(yōu)秀的樣品泵,如AIRCHEK2000美國SKC,升級版airchek touch,通用泵和XR5000氣體采樣泵,提供*品質(zhì)的實驗室和工業(yè)檢測儀器設備。通過專業(yè)、細致和全面的服務實現(xiàn)為客戶創(chuàng)造更多價值。